Reinstall Systems Centre Operations Manager 2012 SP1 Issues (SCOM)


I recently had to reinstall Systems Centre Operations Manager 2012, the initial install was done on the candidate release had no problems however on removing and reinstalling from the SP1 one release I thought I would share with you a couple of issues that arose. 
 
 Firstly the databases that are selected need to have a trading slash otherwise the install will fail as show below
 
 
 
 
 Secondly I continue to have a problem where the date warehouse would not install properly on examining the logs there was an issue with the data access layer.  I found the solution to this was to change the data access account from a local user account to a domain user account.  After making these changes the install completed successfully. 

 
 
 [22:10:45]: Info: :Info:trying to connect with server xxxxx
[22:10:52]: Info: :Info:Error while connecting to management server: The Data Access service is either not running or not yet initialized. Check the event log for more information.
[22:10:52]: Error: :Couldn't connect to mgt server stack: : Threw Exception.Type: Microsoft.EnterpriseManagement.Common.ServiceNotRunningException, Exception Error Code: 0x80131500, Exception.Message: The Data Access service is either not running or not yet initialized. Check the event log for more information.
[22:10:52]: Error: :StackTrace:   at Microsoft.EnterpriseManagement.Common.Internal.ExceptionHandlers.HandleChannelExceptions(Exception ex)
   at Microsoft.EnterpriseManagement.Common.Internal.SdkDataLayerProxyCore.CreateEndpoint[T](EnterpriseManagementConnectionSettings connectionSettings, SdkChannelObject`1 channelObjectDispatcherService)